Water Process Before Entering The Boiler

Water Process Before Entering The Boiler

Water Tube water process before entering the boiler VS Fire Tube boiler

Difference between water tube boiler and fire tube boiler?

June 22, 2018 in the evening around 6:40, Chongqing Hechuan keel village "Ding taste the food factory" water process before entering the boiler exploded, the accident killed two people, three people were injured.

At the scene, boiler room Zhata, damaged boiler flew ten meters outside the field, next to a few factories are subject to different degrees of damage, around the ruins. But because not many nearby residents, no adverse impacts to other villagers.

According food factory owner friends when the accident occurred, both inside and outside the boiler room just five people. One person was killed and four people were injured, one of whom died en route to hospital, the other three in stable condition and is currently being treated in. It is understood, Ding taste the food factory is a small tofu factory, usually only a few factory workers. When the accident occurred, it is time off work, the boss's father, Huang uncle went to the boiler room, prepare a little help, but I do not know which part of improper operation, resulting in an explosion.

The boiler explosion, resulting in serious consequences and impact, but also sounded a warning for the steam boiler is using various food processing plants. Steam boiler output to high-temperature steam, with a certain risk, in use, to operate in strict accordance with the provisions, not miss any details, nor allow non-professional staff stoker boiler operation to avoid unnecessary losses.

1, boiler factory should be accompanied by "technical safety specifications of the design documents, product quality certification, safety and the use and maintenance instructions, supervision and inspection certificate (safety supervision and inspection certificate performance)."

2, boiler installation, maintenance, alteration. Engaged in the installation of the boiler, maintenance, renovation of the unit shall obtain special equipment installation and maintenance certificates issued by the Provincial Quality and Technical Supervision, before engaging in the boiler installation, maintenance, alteration. Construction unit before construction will be prepared for installation, maintenance, alteration in writing inform the special equipment safety supervision and management department of the municipality or district, and will start informing sent to the local county level Quality and Technical Supervision for the record, told immediately after construction.

3, inspection of boiler installation, maintenance, transformation. After construction, the construction unit of Special Equipment To Quality and Technical Supervision, Inspection and declared the boiler installation supervisory inspection and hydrostatic testing. After passing by the Quality and Technical Supervision, Special Equipment Inspection, County of Quality and Technical Supervision involved in overall acceptance.

4, registration boiler. After the boiler inspection, the use of units must be in accordance with the "special equipment registration and use of management rules", fill "boiler (census) Registration Form" to the Quality and Technical Supervision registered, and obtain a "safe use of special equipment registration certificate" .

5, operation of the boiler. Boiler operation must be performed by trained and qualified to obtain "special equipment operator certificate" certified personnel to operate, must strictly abide by the rules and eight systems, six record.

6, check the boiler. Periodic inspection of boiler once a year, not be used without safety periodic inspection of boilers. Safety accessories safety valve of the boiler regular inspection once a year, pressure gauge biannually verified, may not be used without the periodic inspection of the safety accessories.

Matters needing attention and standard flow of water process before entering the boiler periodic sewage discharge operationOperational notes and standardized procedures for boiler periodic discharge: 1. Periodic Sewerage notices 1. The main value of the furnace should be contacted before the discharge is discharged, and the steam turbine can be approved before it can be carried out. 2. When discharging water level is normal, after discharge, check whether each sewage door is closed tight. 3. Sewerage doors should not be opened to more than 30s, can not open two or more sewage doors at the same time, in order to prevent damage to the water cycle. 4. Open the drain door slowly in case of water shock. In case of water shock, close the valve until the shock disappears, and then slowly open the drain door. 5. When operating the valve, you should stand on the side of the valve, strictly prohibited Right to the valve. II. Discharge operation flow 1. After receiving the scheduling task, labor protection supplies dressed neatly, with a special F wrench, on the spot open the general gate. 2. Open all the doors, contact the DCS screen of the furnace to open the corresponding discharge electric door, after the discharge, first close the second door, then close the door, one by one, one by one. All sewerage is over, close once door of each discharge and main gate of sewerage 3. When discharging water, we should pay close attention to the water level. If there is any abnormal water level or accident, the discharge should be stopped. For 2 hours, the door cores of each discharge door shall be checked for leakage, and if the drain is lost, the drain door shall be opened promptly once. Note by removing residue that may be stuck in the core of the door (boiler principal value should be contacted before operation): the whole drainage process should be in close contact with the DCS operator.

About steam water process before entering the boiler superheater tubes 1 Blasting failure, bursting phenomenon superheater tubes a. Steam discharge sound or explosions near the superheater. B. abnormally decreased steam flow, and the flow is not less than the water flow normally. C. furnace pressure is reduced or made positive, the door severe, see the fire and smoke outwardly steam discharge hole. D. flue gas temperature after superheaters abnormally decreased or increased temperature difference before and after the flue gas superheater. Serious E. Damaged, the boiler steam pressure drop. F. exhaust gas temperature decreased significantly, the chimney flue gas into a gray or white color. g. draft fan load is increased, the current increased. 2, the superheater tubes blasting process a. Superheater tubes minor rupture, may be appropriate to reduce the load, maintain operation in a short time, this time should be closely monitored for leakage, at the same time, rapid start standby boiler. If the monitoring process fault conditions worsen, it should be shutdown as soon as possible. b. When severe rupture superheater tubes must emergency shutdown.

[email protected]

GET A QUOTE

  • Name:

  • Email:

  • Ton:

  • Phone:

  • Pressure:

Select:

  • Please tell us the type of boiler you need

  • Please tell us the boiler fuel you will use

Requirement:

We will process the information you submit quickly and ensure that your information is completely confidential.

Water Process Before Entering The Boiler

Water Treatment Program Training Manual - Alberta.ca

2008-5-16·1.0 Closed Hot Water Heating System 1 2.0 Steam Boiler System 6 Revision 2 of the Water Treatment Program Manual was issued in January 1997 in order to include Confirm the operation of the make-up water meter by noting the changes in its reading before and after such activities as water sampling, low-water fuel cut-off controller

Free Chat

unit14_boiler_mounting,managemnent_and

2013-11-1·Safety precautions (should be) taken before entering a boiler connected to another boiler under steam. If this is to be done for a prolonged period it is advisable to allow a current of air to flow through the boiler by removing manhole( ), sighthole() and mudhole covers(

Free Chat

Boilers - Marine Engineering

2014-4-28·These were the most common form of boiler design before the introduction of water tube designs. See Comparisons of water tube and Smoke tube boilers. This style of boiler still see active service were low quantities of low quality steam are required, such as

Free Chat

Water Handbook - Preboiler amp; Industrial Boiler

2 ·The consensus is that feedwater oxygen, iron, and copper content should be very low (e.g., less than 7 ppb oxygen, 20 ppb iron, and 15 ppb copper for a 900 psig boiler) and that pH should be maintained between 8.5 and 9.5 for system corrosion protection. In order to minimize boiler system corrosion, an understanding of the operational

Free Chat

Proper Boiler Feed Water Temperature Management |

Proper Boiler Feed Water Temperature Management Prior to it entering the boiler, the plant manager has the opportunity to control both the boiler feed water temperature as well as its quality. This involves introducing treatment and heating that will provide optimal conditions for a long boiler life.

Free Chat

Boiler Safety Guidelines - Banks Engineering

2007-1-5·The training in safety should be a continuous process for the purpose of educating employees to recognize and to keep safety in their minds throughout their careers. Verify operation of boiler water feed system periodically. Test for toxic or flammable gas. Provide lights before entering a confined space. Oxygen deficiency. Confined or

Free Chat

What is a Feed Water Heater? (with pictures)

2020-4-16·A feed water heater is a device used to gradually heat water that is being delivered to a steam boiler.The main reason why feed water heaters are used is because the water needs to be heated gradually until it reaches its boiling point, also known as the saturation temperature.

Free Chat

» Processing Natural Gas NaturalGas.org

In this process, a liquid desiccant dehydrator serves to absorb water vapor from the gas stream. Glycol, the principal agent in this process, has a chemical affinity for water. This means that, when in contact with a stream of natural gas that contains water, glycol will serve to steal the water out of the gas stream.

Free Chat

Hazard and Operability study in Boiler System of The

2017-6-2·Hazard and Operability study in Boiler System of The Steam Power Plant Ali Musyafa1, Boilers can be divided into three systems of feed water system, steam system and requiring fixed temperature for the process, so before entering the air through the pulverize in pprimary heating

Free Chat

What is a Feed Water Heater? (with pictures)

2020-4-16·A feed water heater is a device used to gradually heat water that is being delivered to a steam boiler.The main reason why feed water heaters are used is because the water needs to be heated gradually until it reaches its boiling point, also known as the saturation temperature.

Free Chat

Water Treatment for High Pressure Boilers in Sugar Plant

2011-4-5·Water Treatment for High Pressure Boilers in Sugar Plants Impurities present in water used for steam generation and other power plant and process duties may cause trouble by forming deposits on component and equipment surfaces, thus Oxygen (O2) and other gases are removed from feed water before they can enter the boiler. Removal is

Free Chat

What Is a Boiler Feed Water Treatment System and

For industrial companies using a boiler for its facility, some type of boiler feed water treatment system is usually necessary to ensure an efficient process and quality steam generation. The most appropriate boiler feed water treatment system will help the facility avoid costly plant downtime, expensive maintenance fees, and boiler failure as a result of scaling, corrosion, and fouling of the

Free Chat

Correct procedure for water filling in boiler -

2020-4-23·Drum water filling is a very important activity before boiler light up . in boiler hydrostatic test we also filling the drum with above method but in this condition little bit variation in the process of water filling . first of all insure that the suitable D.M water level is available in deaerator after that check out healthyness of the boiler feed pump . before start up of the boiler feed

Free Chat

Using Reverse Osmosis for Boiler Pretreatment

2015-11-3·Pretreatment 44 Disadvantages of RO as compared to a softener boiler pretreatment program include: x Increased electrical costs. x If acid pretreatment is used, acid handling will be required. x Product water flow rate is pretty much fixed while ion exchange can manage variable flows. x An antiscalant may be necessary upstream of the RO. x With polyamide (PA) membranes, chlorine

Free Chat

Boiler Water Level Controller: Components amp; Working,

2020-5-9·Before going further lets go through the feed water system for the boiler. Two types of feed water system are shown here: In this system, two Feedwater pumps are there(one is standby for other). A three-valve is provided which controls the amount of feed water entering the boiler. When a large quantity of water is required, because of a

Free Chat